BAB IV
HASIL DAN PEMBAHASAN
4.1 Data dan Hasil Perhitungan Steam Turbine Generator (STG)
4.1.1 Data Performance Test STG
Berdasarkan hasil performance test pada Steam Turbine Generator 51-G-101 A/B/C/D/E yang dilakukan tanggal 21 Januari 2011 di Unit Utilitas Pertamina RU VI Balongan, maka diperoleh data kondisi operasi dan daya yang dihasilkan, ditabulasi pada tabel 4.1.
Tabel 4.1 Data Hasil Performance Test STG (51-G-101 A/B/C/D/E)
Jenis STG 51-G-101 A/B/C/D/E
|
P inlet (kPa)
|
Steam Flow (kg/jam)
|
T inlet (0C)
|
Power (kW)
|
|
STG A (GE = 0)
|
12 MW
|
59700
|
4190,350
|
370
|
12030
|
14 MW
|
70300
|
4179,563
|
370
|
14010
|
|
16 MW
|
81000
|
4171,718
|
370
|
16222
|
|
18 MW
|
90000
|
4167,795
|
370
|
18030
|
|
STG B (GE = 0)
|
12 MW
|
61900
|
4138,375
|
370
|
11900
|
14 MW
|
72200
|
4132,491
|
370
|
14160
|
|
16 MW
|
81900
|
4124,646
|
370
|
16060
|
|
18 MW
|
91200
|
4116,801
|
370
|
17900
|
|
STG C (GE = 0)
|
12 MW
|
58100
|
4185,447
|
370
|
12080
|
14 MW
|
68500
|
4168,776
|
370
|
14010
|
|
16 MW
|
77200
|
4157,008
|
370
|
15910
|
|
18 MW
|
87000
|
4145,240
|
370
|
18000
|
|
STG D (GE = 0)
|
12 MW
|
56300
|
4223,692
|
370
|
12040
|
14 MW
|
65200
|
4214,867
|
370
|
14000
|
|
16 MW
|
74200
|
4211,925
|
370
|
15910
|
|
18 MW
|
83500
|
4203,099
|
370
|
17990
|
|
STG E (GE = 0)
|
12 MW
|
63000
|
4099,149
|
373
|
12070
|
14 MW
|
74000
|
4099,149
|
373
|
14120
|
Keterangan : GE = Generator Extraction
Untuk STG E maksimal power yang dapat dihasilkan (load maximal) = 14 MW
Data pada Tabel 4.1 digunakan untuk menghitung nilai efisiensi yang akan dijadikan
parameter dalam menunjukkan kinerja STG aktual.
4.1.2 Hasil Perhitungan Efisiensi STG
Setelah
dilakukan perhitungan, maka didapatkan hasil berupa nilai efisiensi turbin dan theoritical steam rate (TSR) dari masing-masing STG. Tabel 4.2 menunjukkan nilai efisiensi turbin pada performance test STG
Tabel 4.2 Nilai Efisiensi Turbin pada Performance Test STG
Jenis STG
(51-G-101 A/B/C/D/E)
|
Actual Steam Rate
|
Theoritical Steam Rate
|
Efisiensi Turbin (%)
|
|
(kg/kW.jam)
|
(kg/kW.jam)
|
|||
STG Desain
(GE = 0)
|
22 MW
|
97.000
|
78799,990
|
80,237
|
STG A
(GE = 0)
|
12 MW
|
59700
|
43166,776
|
72,306
|
14 MW
|
70300
|
51435,204
|
73,165
|
|
16 MW
|
81000
|
60431,244
|
74,606
|
|
18 MW
|
90000
|
67833,338
|
75,370
|
|
STG B
(GE = 0)
|
12 MW
|
61900
|
41478,424
|
67,009
|
14 MW
|
72200
|
47582,457
|
65,904
|
|
16 MW
|
81900
|
54913,636
|
67,050
|
|
18 MW
|
91200
|
62660,915
|
68,707
|
|
STG C
(GE = 0)
|
12 MW
|
58100
|
42523,275
|
73,190
|
14 MW
|
68500
|
50008,689
|
73,005
|
|
16 MW
|
77200
|
57456,068
|
74,425
|
|
18 MW
|
87000
|
65780,406
|
75,610
|
|
STG D
(GE = 0)
|
12 MW
|
56300
|
40722,369
|
72,331
|
14 MW
|
65200
|
47376,006
|
72,663
|
|
16 MW
|
74200
|
53842,626
|
72,564
|
|
18 MW
|
83500
|
61953,028
|
74,195
|
|
STG E
(GE = 0)
|
12 MW
|
63000
|
43897,645
|
69,679
|
14 MW
|
74000
|
52244,376
|
70,601
|
Keterangan : GE = Generator Extraction
Berdasarkan data hasil perhitungan efisiensi pada Tabel 4.2, dapat diketahui
bahwa kebutuhan steam untuk mengoperasikan STG sudah melebihi dari kebutuhan steam teoritis. Hal ini terjadi karena suatu STG tidak dioperasikan dalam kondisi isentropik, dimana keadaan tersebut merupakan kondisi ideal suatu sistem
turbin. STG secara aktual dioperasikan pada keadaan adiabatik ireversibel. Oleh karena itu, terdapat perbedaan jumlah kebutuhan steam aktual dengan teoritis. Perbedaan tersebut akan menunjukkan seberapa besar kinerja dari suatu STG yang biasa dikenal dengan sebutan efisiensi. Terdapat
dua jenis efisiensi pada suatu sistem turbin, yaitu efisiensi termal dan efisiensi turbin.
Untuk
meninjau lebih jauh mengenai kinerja STG pada Unit 51 RU VI Balongan, maka parameter yang dapat dijadikan indikator adalah perbandingan nilai efisiensi aktual dan desain serta perbandingan kebutuhan steam aktual dengan kebutuhan steam desain.
Steam Turbine Generator (STG) 51-G-101 A/B/C/D/E) merupakan unit pembangkit
listrik tenaga uap yang dioperasikan pada Unit Utilitas (Unit 51) Pertamina RU VI Balongan. Alat ini berfungsi memproduksi energi listrik untuk menyuplai seluruh kebutuhan operasional kilang Balongan. Umpan STG adalah High
Pressure Steam (HPS) yang diperoleh dari unit boiler.
Berikut grafik 4.1 menunjukkan hubungan kebutuhan steam dengan daya/power yang
dihasilkan pada masing-masing STG.
itu cara menghitung efisiensi turbin bagaimana?